Nitrox basics
Nitrox is air with more oxygen and less nitrogen. For most divers it is the first gas beyond air, and on dives between about 15 and 40 meters it brings longer no-stop times. It also brings a new limit: below a certain depth the oxygen itself becomes dangerous. This guide explains what nitrox does, which limits apply and how to choose the mix for a dive.
What nitrox is
Air holds about 21 % oxygen and 79 % nitrogen, with argon and the other trace gases counted as nitrogen. Nitrox, or enriched air nitrox (EANx), is any mix of oxygen and nitrogen with more than 21 % oxygen. The number names the oxygen: EAN32 holds 32 % oxygen and 68 % nitrogen, EAN36 holds 36 % oxygen. EAN32 and EAN36 are the classic mixes for recreational dives; technical divers carry EAN50 and pure oxygen as deco gases to shorten their decompression.
Why less nitrogen helps
Under pressure the body takes up nitrogen from the breathing gas and has to release it again on the ascent. The deeper and longer the dive, the more nitrogen the tissues hold, and this load limits how long a diver may stay without decompression stops. With less nitrogen in the gas, the tissues take up less of it at the same depth: the no-stop time grows, or the same dive ends with a smaller load and a wider safety margin.
How much nitrogen a nitrox dive brings shows in the equivalent air depth (EAD): the depth at which air holds as much nitrogen as the nitrox does at the real depth.
EAD = (1 − FO2) / 0.79 × (D + 10) − 10
- EAD
- equivalent air depth in meters
- FO2
- fraction of oxygen in the mix, e.g. 0.32 for EAN32
- D
- real depth in meters
- 0.79
- fraction of nitrogen in air
- 10
- meters of water per bar
EAN32 at 30 m gives 0.68 / 0.79 × 40 − 10 = 24.4 m. For the nitrogen, a dive to 30 m on EAN32 is a dive to about 24 m on air, and an air table gives it the no-stop time of that shallower depth. The EAD calculator rounds up to 24.5 m, so a table is always read at least as deep as needed.
Two common beliefs are not backed by the evidence. Nitrox is not less narcotic than air: oxygen is considered about as narcotic as nitrogen, so the narcosis at a given depth stays the same. And that divers feel less tired after a nitrox dive has not been confirmed in controlled studies.
The oxygen limit: ppO2
The body needs oxygen, but at a high pressure it becomes toxic. By Dalton's law each gas of a mix contributes its share to the total pressure, so the partial pressure of oxygen (ppO2) is its fraction times the ambient pressure:
ppO2 = FO2 × (D / 10 + 1)
- ppO2
- partial pressure of oxygen in bar
- D / 10 + 1
- ambient pressure in bar at the depth D in meters
EAN32 at 30 m reaches 0.32 × 4 = 1.28 bar, while air at the same depth stays at 0.84 bar. The ppO2 calculator rounds up to the next tenth, 1.3 bar, so a limit is never hidden.
The danger is oxygen toxicity of the central nervous system (CNS): above a certain ppO2 it can cause convulsions without warning, which under water usually means drowning. The training agencies therefore set limits:
- 1.4 bar for the working part of a dive, at the bottom.
- 1.6 bar as the absolute maximum, for decompression stops where the diver rests.
- 0.16 bar as the lower limit, below which a gas does not keep a diver conscious. Nitrox never comes close to it, trimix does.
Time counts as well: the higher the ppO2, the shorter the body tolerates it. The NOAA limits allow 150 minutes at 1.4 bar for a single dive, but only 45 minutes at 1.6 bar. Dive computers follow this as the CNS percentage.
The maximum operating depth (MOD)
From the ppO2 limit follows the deepest point a mix may be breathed at:
MOD = (ppO2 / FO2 − 1) × 10
- MOD
- maximum operating depth in meters
- ppO2
- the limit in bar, e.g. 1.4
EAN32 with 1.4 bar gives (1.4 / 0.32 − 1) × 10 = 33.75 m; the MOD calculator rounds down to 33 m. With 1.6 bar the same mix reaches 40 m, but that is the limit for an emergency, not a depth to plan the dive to. The richer the mix, the shallower its MOD:
| Mix | MOD at 1.4 bar | MOD at 1.6 bar |
|---|---|---|
| EAN32 | 33 m | 40 m |
| EAN36 | 28 m | 34 m |
| EAN40 | 25 m | 30 m |
| EAN50 | 18 m | 22 m |
Going below the MOD is the one real danger of nitrox. A diver who drifts down along a wall or follows a buddy deeper raises the ppO2 quickly. Know the MOD of the gas in your tank and keep an eye on the depth.
Choosing a mix
There are two ways to it. The first starts from the depth: the best mix is the one with the most oxygen whose ppO2 at the deepest point of the dive stays within the limit.
FO2 = ppO2 / (D / 10 + 1)
For a dive to 30 m with 1.4 bar this is 1.4 / 4 = 0.35, so EAN35; for 25 m it is EAN40. The Best Mix calculator rounds down to whole percent, so the mix stays within the limit. Many divers plan with 1.3 bar to keep a margin for a few meters deeper than planned: for 30 m that gives EAN32.
The second way starts from what is on offer. Many dive centers fill only EAN32 or EAN36; then check that the MOD of the mix lies deeper than the deepest point of the dive, with a margin. The richer the mix, the longer the no-stop time, but the shallower the MOD: a mix chosen for 25 m does not belong on a dive that may go to 35 m.
Before every dive
- Analyse the gas yourself with an oxygen analyser and sign the fill log. A tank can hold something else than what was ordered.
- Label the tank with its oxygen and its MOD.
- Set your dive computer to the mix you analysed.
- Nitrox needs training: most filling stations only fill it for divers with a nitrox certification. In many places, mixes with more than 40 % oxygen need equipment that is cleaned and approved for oxygen.
This guide explains the principles; it does not replace a nitrox course. Check results against a second source before you dive with them; see the legal notice.