Gas Blending
Partial pressure blending fills a tank with nitrox or trimix by adding helium, oxygen and air one after the other and reading only the pressure gauge. This calculator tells you how many bar of each gas to add. Enter what is in the tank now (pressure, oxygen and helium) and the mix you want at the end. Choose one of your tanks to also see the liters of each gas, and a filling station to see what the fill costs.
Dalton's Law says that each gas in a mixture contributes its share to the total pressure. A tank filled to 200 bar with 35 % helium therefore holds 70 bar of helium, no matter in which order it went in. Partial pressure blending uses this: every gas is added as a number of bar, and the gauge shows when to stop.
The tank is filled in this order: first helium, then oxygen, and finally air up to the end pressure. Helium and oxygen go into the tank while the pressure is still low, and topping up with air mixes the gases and brings the tank to its final pressure. Nitrogen can only come from air, so the amount of air is fixed by the nitrogen the mix needs, and the oxygen in that air counts towards the oxygen of the mix:
PHe = FHe,end × Pend − FHe,rest × Prest
Pair = (FN2,end × Pend − FN2,rest × Prest) / 0.79
PO2 = FO2,end × Pend − FO2,rest × Prest − 0.21 × Pair
- PHe, PO2, Pair
- bar of helium, oxygen and air to add
- Pend
- desired end pressure in bar
- Prest
- pressure of the gas left in the tank before blending, in bar
- F…,end, F…,rest
- fraction of the gas in the desired mix and in the gas left in the tank, e.g. 0.35 for 35 % helium; nitrogen is what is left after oxygen and helium
- 0.79, 0.21
- fractions of nitrogen and oxygen in air
An example: an empty tank is to be filled to 200 bar of trimix 21/35. The mix needs 0.35 × 200 = 70 bar of helium. Its 44 % nitrogen are 88 bar, which come with 88 / 0.79 = 111.4 bar of air. That air already brings 0.21 × 111.4 = 23.4 bar of oxygen, so of the 0.21 × 200 = 42 bar of oxygen only 18.6 bar have to be added as pure oxygen. The fill is 70 bar of helium, then 18.6 bar of oxygen to 88.6 bar, then air to 200 bar.
A gauge is read in whole bar, so the calculator rounds the gauge after each gas to a whole bar, and a gas adds the difference between two such readings. The fill above becomes 70 bar of helium, oxygen to 89 bar and air to 200 bar. The steps always end at the desired pressure, and a gas that leaves the reading at the same whole bar is left out.
Because every bar of nitrogen brings 21/79 bar of oxygen along, the part of the mix that is not helium must contain at least 21 % oxygen. A mix with less oxygen would need nitrogen without the oxygen of the air, which this way of blending cannot deliver. A trimix with 70 % helium, for instance, needs at least 7 % oxygen; the calculator refuses mixes below this limit.
Sometimes the gas left in the tank does not fit the desired mix: it contains more helium or nitrogen than the end mix may hold, or it is richer in oxygen than air, so even topping up with air would end with too much oxygen. The formulas would then ask for a negative amount of gas. In that case the tank has to be drained first, and the calculator shows the pressure to drain it to. For example, a tank with 100 bar of EAN50 that is to become 200 bar of EAN32 has to be drained to 75 bar; after that it takes 0.3 bar of oxygen and 124.7 bar of air. In whole bar the oxygen is left out and air fills the tank to 200 bar, which gives EAN32 within 0.2 %. The tank is always drained to the whole bar below the calculated pressure; draining a little more never hurts.
Pure oxygen makes many materials burn that are safe in air. Only blend with tanks, valves and fittings that are cleaned and approved for oxygen, open the valves slowly and fill slowly, so that the gas does not heat up. Analyse the finished mix before every dive and label the tank. Partial pressure blending belongs in the hands of trained gas blenders.
Read more in the guide: Partial pressure blending